Single-end service assembled chambers CSR 207V series

Single-end service assembled chambers CSR-207V are designed for power facilities with 3-phase AC power (50/60 Hz) of 6 and 10 kV with resonant earthed or isolated neutral and correspond to technical specifications BKZHI.674712.002 TU.

CSR are manufactured both to meet the needs of the country's economy and for export and are used as switchgear, including modular ones of 6 - 10 kV, used to receive and distribute power to industrial and agricultural facilities, power supply stations and substations for railway transport. Operating principle is based on the main and auxiliary circuits of the chambers.

CSR chambers can be used as a high-voltage device (HVD) for compact transformer substations of the KTP-10/0.4, BMKTP-10/0.4 series with a capacity from 100 to 2500 kVA.

Climatic version - N and T, location category - 3 as per GOST 15150-69.

Detailed information

Main parameters and characteristics

Nominal values of environmental climatic factors are as per GOST 15150-69 and GOST 15543.1-89.

And:

  • ambient temperature range: from -45 to +40 º, for chambers with SIEMENS SION switch - from -25 to +40 º;
  • type of atmosphere - II (industrial) as per GOST 15150-69;
  • altitude above sea level should not exceed 1000 m.
  • explosion-proof environment, free from conductive dust, aggressive vapors and gases that destroy insulation and metals;

The following types of switches are used in the CSR chambers as switching devices:

  • ВВ/ТЕL-10/630-1000 corresponds to TSHAG.674152.004 TU;
  • ВБ-10-20/630-1600 corresponds to KUIUZH.674152.012 TU;
  • SIEMENS SION 3АЕ1 800, 1250 corresponds to IEC (DIN EN) 60265-1.

Upon request of the customer switches of other types and manufacturers can be installed.

CSR are manufactured:

  • according to the main circuit diagrams specified in Appendix B;
  • according to typical auxiliary circuit diagrams, specified in volume II;
  • according to the main and auxiliary circuit diagrams provided by the customer.

The manufacturer reserves the right to replace the above devices with similar ones.

 

Technical characteristics

Name of the parameter Value

Rated voltage (linear), kV

  • at a frequency of 50 Hz
  • at a frequency of 60 Hz

 

6; 10
6,6; 11

Rated operating voltage (linear), kV 7,2; 12

Rated current of the main circuits, A

  • at a frequency of 50 Hz
  • at a frequency of 60 Hz

 

630; 1000; 1600
800; 1250; 1600

Rated cut-off current, kA 12,5; 20; 25; 31,5
Thermal resistance current (three-second current), kA 20; 31,5
Current of electrodynamic stability, kA 51; 81
* Rated current of current transformers, A 50; 75; 100; 150; 200; 300; 400; 600; 800; 1000; 1500

Rated busbar current, A

  • at a frequency of 50 Hz
  • at a frequency of 60 Hz

 

630; 1000; 1600
800; 1250; 1600

Rated current of bus bridges, A

  • at a frequency of 50 Hz
  • at a frequency of 60 Hz

 

630; 1000; 1600
800; 1250; 1600

Rated voltage of auxiliary circuits, V:

- DC and AC protection, control and alarm circuits, V
- voltage transformer circuits, V
- transformer circuits of own needs, V

Lighting circuits:

- inside the CSR chamber, V
- CSR camera facade, V

 

220
100
220; 380


12
12

The fuse insertion current of the power fuse, A 3,2; 5; 8; 10; 16; 20; 31,5 ÷ 160
Rated power of transformers for own needs, kVA 40
* Thermal and electrodynamic resistance of current transformers according to their technical parameters.

Characteristics of devices installed in CSR

Naming of indicators Execution
Insulation level according to GOST 1516.1 With normal insulation
Type of insulation

Aerial

Combined

The presence of insulation of the current-carrying busbars of the main circuits

With uninsulated tires

With insulated tires

The presence of roll-out elements in the camera

With roll-out elements

Without roll-out elements

Busbar system With one busbar system
Terms of Service With one-way and two-way service
Type of linear high-voltage inputs (connections) Cable and busbars
The presence of doors in the compartment of the pull-out trolley Cameras with doors
Type of management

Local

Remote control

Degree of protection according to GOST 14254 IP30
Type of cameras depending on the installed equipment

- with high voltage switches;

- with detachable contact connections;

- with voltage transformers;

- with power fuses;

- with power transformers;

- with static capacitors;

- with vacuum contactors

- combined (with voltage transformers and arresters).

Implementator

SHIELD Engineering and manufacturing complex

The manufacturing division performs a complete cycle from welding metal structures for modular enclosures to turn-key ready equipping. The workshops are equipped with state-of-the-art multifunctional manufacturing equipment: automated laser cutting machines,…

Read more →

Order equipment

Make a request

Specialists of JSC «Cheboksary electrical apparatus plant» will help you in a timely manner to resolve any difficulties that arise, clarify something, answer any question, issue an application